Modern office building
Home / Professionals / Fire-rated facadesFire resistance · EN 13501-2

Fire-rated facades

Fire-resistant glazed facades and fire stopping between facade and slabs, protecting the occupants of public buildings, offices and buildings open to the public.

Protection

Stopping fire from spreading floor to floor

In a fire, the facade is a fast route for flames and smoke from one floor to the next. Regulations therefore require fire resistance for certain facade zones and for the junctions between facade and floors.

We install fire-rated curtain walls and glazing, and slab-edge fire stopping, using tested and certified systems installed to their manufacturers' instructions.

Technical sheet

Classification
EN 13501-2 (E, EI)
Elements
Fire-rated curtain walls and glazing
Junctions
Slab-edge fire stopping
Partner
Hilti
Use
Public buildings, offices, residential blocks

Classes and durations depend on the project and the certified system selected.

Our approach

Installation as rigorous as the system

Certified systems

Only systems tested for the required class.

Compliant installation

Strict adherence to manufacturers' details.

Traceability

Installation records and product data for the as-built file.

Coordination

Interfaces worked out with the structure and other trades.

Aesthetics

Fire-rated facades that blend with the rest of the envelope.

Inspection

Self-checks and handover with the inspection body.

Method

From design to handover

Design and layout

Review of specifications, drawings and details; facade layout and choice of systems.

Shop drawings

Technical details, calculations and samples submitted for approval.

Fabrication and QC

Manufacturing of elements and quality control before shipping.

Logistics and installation

Phased deliveries to suit the programme, installed by our teams.

Handover

Inspections, snagging and as-built documentation.

Frequently asked questions

Your questions

What do E and EI mean?

E stands for integrity against flames and hot gases; EI adds insulation, limiting the temperature on the unexposed side. The number that follows (30, 60…) is the duration in minutes.

Who sets the fire resistance requirements?

The applicable fire regulations, specified by the architect, engineers and fire service. We install solutions that meet those requirements.

A facade project to price?

Send us your drawings, specifications and schedule: our team will review your file and come back with an offer.

Send your file